Serial Parameters RX TX 1 Center Frequency (F0) 822.5MHz 867.5MHz 2 Pass Band Frequency 815~830MHz 860~875MHz 3 Pass Band Insertion Loss ≤1.0dB ≤1.0dB 4 Pass Band Ripple ≤0.5dB ≤0.5dB 5 Pass Band
Serial Parameters PORT 2 PORT 3 1 Center Frequency (F0) 376MHz 400MHz 2 Pass Band Frequency 374~378MHz 398~402MHz 3 Pass Band Insertion Loss ≤0.9dB ≤0.9dB 4 Pass Band Return Loss ≥20dB ≥20dB 5 St
Serial Parameters PORT 2 PORT 3 1 Center Frequency (F0) 470.5MHz 500MHz 2 Pass Band Frequency 468.5~472.5MHz 498~502MHz 3 Pass Band Insertion Loss ≤0.9dB ≤0.9dB 4 Pass Band Return Loss ≥20dB ≥20dB
Serial Parameters PORT 2 PORT 3 1 Center Frequency (F0) 564.5MHz 600MHz 2 Pass Band Frequency 562.5~566.5MHz 598~602MHz 3 Pass Band Insertion Loss ≤0.9dB ≤0.9dB 4 Pass Band Return Loss ≥20dB ≥20dB
Serial Parameters RX TX 1 Center Frequency 361MHz 369MHz 2 Bandwidth 2MHz (360~362MHz) 2MHz (368~370MHz) 3 Insertion Loss ≤1.5dB ≤1.5dB 4 VSWR ≤1.3:1 ≤1.3:1 5 Rejection ≥35dB @ 368~370MHz ≥35dB @
Serial Parameters RX TX 1 Center Frequency 491MHz 506MHz 2 Pass Band Frequency 490~492MHz 505~507MHz 3 Insertion Loss ≤2.8dB ≤2.8dB 4 VSWR ≤1.3:1 ≤1.3:1 5 Rejection ≥75dB @ 505~507MHz ≥75dB @ 490
Serial Parameters RX TX 1 Center Frequency [F0] 1950MHz 2140MHz 2 Pass Band Frequency 1920~1980MHz 2110~2170MHz 3 Insertion Loss ≤1.5dB ≤1.5dB 4 Ripple in Band ≤1.0dB ≤1.0dB 5 VSWR ≤1.3:1 ≤1.3:1
Serial Parameters RX TX 1 Center Frequency [F0] 1762.5MHz 1857.5MHz 2 Pass Band Frequency 1745~1780MHz 1840~1875MHz 3 Insertion Loss ≤1.5dB ≤1.5dB 4 Ripple in Band ≤1.0dB ≤1.0dB 5 VSWR ≤1.3:1 ≤1.
Serial Parameters CH1 CH2 1 Center Frequency (F0) 2025MHz 2300MHz 2 Pass Band Frequency 1950~2100MHz 2200~2400MHz 3 Pass Band Insertion Loss ≤1.2dB ≤1.2dB 4 Pass Band Return Loss ≥18dB ≥18dB 5 St
Serial Parameters CH1 CH2 1 Center Frequency (F0) 1880MHz 1960MHz 2 Pass Band Frequency 1850~1910MHz 1930~1990MHz 3 Pass Band Insertion Loss ≤1.3dB ≤1.3dB 4 Pass Band Return Loss ≥18dB ≥18dB 5 St
Serial Parameters RX TX 1 Center Frequency (F0) 382.5MHz 392.5MHz 2 Pass Band Frequency 380~385MHz 390~395MHz 3 Pass Band Insertion Loss ≤1.8dB ≤1.8dB 4 Pass Band VSWR ≤1.3:1 ≤1.3:1 5 Stop Band R
Serial Parameters RX TX 1 Center Frequency (F0) 402MHz 467MHz 2 Pass Band Frequency 399~405MHz 464~470MHz 3 Pass Bans Insertion Loss ≤0.5dB ≤0.5dB 4 Pass Bans Ripple ≤0.2dB ≤0.2dB 5 Pass Bans Ret
Serial Parameters RX TX 1 Center Frequency(F0) 5775MHz 5915MHz 2 Pass Band Bandwidth 27MHz (5761.5~5788.5MHz) 27MHz (5901.5~5928.5MHz) 3 Pass Band Insertion Loss ≤2.0dB ≤2.0dB 4 Pass Band Return L
Serial Parameters RX TX 1 Center Frequency(F0) 5745MHz 5885MHz 2 Pass Band Bandwidth 27MHz (5731.5~5758.5MHz) 27MHz (5871.5~5898.5MHz) 3 Pass Band Insertion Loss ≤2.0dB ≤2.0dB 4 Pass Band Return L
1 Center Frequency(F0) 1795MHz 2045MHz 2 Pass Band Frequency 1710 ~ 1880MHz 1920 ~ 2170MHz 3 Pass Band Insertion Loss ≤1.3dB ≤1.3dB 4 Pass Band VSWR ≤1.4:1 ≤1.4:1 5 Stop Band Attenuation ≥60dB @ 1
1 Center Frequency(F0) 4512.5MHz 4887.5MHz 2 Pass Band Frequency 4400 ~ 4625MHz 4775 ~ 5000MHz 3 Pass Band Insertion Loss ≤1.25dB ≤1.25dB 4 Pass Band Return Loss ≥18dB ≥18dB 5 Stop Band Rejection
1 Center Frequency(F0) 2480MHz 2500MHz 2 Pass Band Frequency 2475 ~ 2485MHz 2499 ~ 2501MHz 3 Pass Band Insertion Loss ≤2.0dB ≤2.0dB 4 Pass Band Return Loss ≥18dB ≥18dB 5 Isolation ≥50dB @ 2475 ~ 2
1 Center Frequency (F0) 1842.5MHz 2140MHz 2 Pass Band Frequency 1805~1880MHz 2110~2170MHz 3 Pass Band Insertion Loss ≤1.0dB ≤1.0dB 4 Pass Band VSWR ≤1.3:1 ≤1.3:1 5 Stop Band Attenuation ≥70dB @ 21
1 Center Frequency(F0) 780MHz 850MHz 2 Pass Band Frequency 750 ~ 810MHz 830 ~ 870MHz 3 Pass Band Insertion Loss ≤1.2dB ≤1.2dB 4 Pass Band VSWR ≤1.3:1 ≤1.3:1 5 Stop Band Rejection ≥25dB @ 830 ~ 870
1 Center Frequency(F0) 882.5MHz 945MHz 2 Pass Band Frequency 865 ~ 900MHz 925 ~ 965MHz 3 Pass Band Insertion Loss ≤1.3dB ≤1.3dB 4 Pass Band VSWR ≤1.3:1 ≤1.3:1 5 Stop Band Rejection ≥40dB @ 925 ~ 9